| Haemostasis
Reagents |
Product
Nr |
Package
size |
| PT-REAGENTS
(COMBINED) |
|
|
|
Thrombotest™
Thrombotest™ is a combined prothrombin time (PT) reagent. The
reagent is lyophilized and contains bovine brain thromboplastin and
adsorbed bovine plasma. Thrombotest™ is sensitive both to the
depression of factors II, VII, X and to the presence of PIVKA
factors.
Thrombotest™ is especially suited for control of oral
anticoagulant therapy.
The ISI-value is about 1.0.
|
1003762
1002305
|
12 x 2.2 mL
(96 tests)
6 x 11 mL
(240 tests)
|
| Thrombotest™
Automated
Thrombotest™ Automated is a new version of Thrombotest™ with
qualities important for certain automated coagulation instruments.
|
1002331
|
6 x 11 mL
(240 tests)
|
|
Calcium
Chloride 3.2 mM
To be used with Thrombotest™ and Thrombotest™ Automat.
|
1052882
|
6 x 12 mL
|
|
Normotest™
Normotest™ is a combined prothrombin time (PT) reagent. The
reagent is lyophilized and contains rabbit brain thromboplastin and
adsorbed bovine plasma. Normotest™ is sensitive to the depression
of factors II, VII and X.
Normotest™ can be used both as a screening test for the
extrinsic coagulation system, as a liver function test and for
control of oral anticoagulant therapy.
|
1002473
1002467
|
12 x 2.2 mL
(240 tests)
6 x 11 mL
(240 test)
|
|
Normotest
Automated™
Normotest™ Automated is the same reagent as Normotest™, but
without the green colour added.
|
1002461
|
6 x 10 mL
(240 tests)
|
| Nycotest®
PT
Nycotest® PT is a combined prothrombin time (PT)
reagent. The reagent is lyophilized and contains rabbit brain
thromboplastin and adsorbed bovine plasma. Nycotest® PT
is sensitive to the depression of factors II, VII and X but intensitive
to heparin.
Nycotest® PT can be used both as a screening test for
the extrinsic coagulation system, as a liver function test and
for control of oral anticoagulant therapy.
The ISI-value is about 1.0.
|
1002492
1002488
|
6 x 2 mL reagent
6 x 2 mL rec. liq (60 tests)
3 x 10 mL reagent
3 x 10 rec.liq (150 tests)
|
|
Dilution
Liquid Nycotest®PT
Dilution Liquid Nycotest® PT is a citrate-barbiturate
buffer. To be used with Nycotest® PT.
|
1002485
|
10 x 80 mL
|
| PT-REAGENTS
(PLAIN) |
|
|
| Nycoplastin™
Nycoplastin™ is a plain prothrombin time (PT) reagent according
to the method of Quick. The reagent is lyophilized and contains
rabbin brain thromboplastin added calcium.
Nycoplastin™ is sensitive to the depression of factors II, V,
VII, X and fibrinogen but intensitive to heparin. Nycoplastin™
is a "low" ISI-reagent with an ISI of about 1.2.
Nycoplastin™ can be used both as a screening test for the
extrinsic coagulation system, as a liver function test and for
control of oral anticoagulant therapy.
|
1002448
1002446
|
12 x 2 mL
(120 tests)
6 x 10 mL
(300 tests)
|
| APTT-REAGENT |
|
|
| Cephotest™
Cephotest™ is an activated partial thromboplastin time (APTT)
test.
Cephotest™ is presented as a liquid reagent containing a soluble
activator prepared from ellagic acid. Cephotest™ can be used as
screening test for the intrinsic coagulation system, in diagnosis
and treatment of hemophiliacs, and for control of heparin therapy.
|
1006541
1004948
|
1 x 5 mL
(50 tests)
10 x 5 mL
(500 tests)
|
| Calcium
Chloride 20 mM
To be used with Cephotest™.
|
1002340
|
6 x 20 mL
|
| CONTROL
PLASMAS AND CALIBRATORS: |
|
|
| Control
Plasma Normal
Control Plasma Normal is prepared from human, nonactivated
plasmas and is especially suited for quality control of coagulation
analysis within the normal range.
|
1002387
|
6 x 0.6 mL
|
| Control
Plasma Abnormal
Control Plasma Abnormal is prepared from human, nonactivated
plasmas and is made for the quality control of coagulation analysis
within the abnormal range.
|
1002383
|
6 x 0.6 mL
|
| Control
Plasma AK
Control Plasma AK is prepared from nonactivated plasmas from
donors on stabilized oral anticoagulant therapy. Control Plasma AK
is therefore especially suited for the quality control of methods
used for control of oral anticoagulant treatment.
|
1002375
|
6 x 0.6 mL
|
| Control
Plasma Heparin
Control Plasma Heparin is prepared from human, nonactivated
plasmas which have been added heparin in vitro. Control Plasma
Heparin is made for the quality control of APTT-methods.
|
1002365
|
6 x 0.6 mL
|
| Calibration
Set*
Calibration Set is a set of three different plasmas (human) to be
used for calibration on instruments. Reagent specific
INR-value is given for Thrombotest™, Nycotest®
PT and Nycoplastin™.
|
1048851
|
3 x 2 vials
|
| FDP-KIT |
|
|
| NycoCard®
D-Dimer
NycoCard® D-Dimer is a rapid (2 minutes) immunoassay
for determination of the fibrin degradation product D-dimer in
plasma. The results are measured instrumentally by NyocoCard®
READER II in the range from 0.1 ml/l up 20.0 mg/L, or visually by
comparison to a reference colour chart (5 levels).
|
1048850
1048849
|
48 tests
12 tests
|
| NycoCard®
READER
II kit
NycoCard® READER II is a small, battery operated,
portable instrument for measurement of analyte concentrations
obtained by using the NycoCard® tests.
|
1113117
|
|
| Haemostasis Instruments |
Product Nr |
Package size |
| Thrombotrack™
1 channel (incl. balldispenser)
For clot detection. A rotating steel ball with 125 rpm. is
scanned by means of a reflex sensor. When the ball stops the time is
recorded.
|
1005929
|
1 x 1
|
| Thrombotrack™
1 channel
Same principle but the ball rotates with 250 rpm.
|
1005931
|
1 x 1
|
The
accessories for Thrombotrack™
1 channel:
Automatpipette 5-50 µl
Automatpipette 50-200 µl
Cuvettes
Steel balls
|
1003378
1030480
1109651
1003382
|
1 x 1
1 x 1
1 x 500
1 x 500
|
| Thrombotrack™
2 channel
The same measuring principle as for the 1 and 4 channel.
Calibration curves can be stored and printer can be connected.
|
1054880
|
|
The
Accessories for the Thrombotrack™
2 channel:
Printer
Thermopaper
Reagent cups
Cuvette racks + balls
Automatpipette 5-50µl
Automatpipette 5-200µl
|
1111506
1054878
1054881
1003386
1003378
1030480
|
1 x 1
1 x 5
1 x 100
1 x 1000
1 x 1
1 x 1
|