pH/ISI/LETKENLK/OKSJEN/HIGRO/LM

Pocket Testers for EC, pH, C, TDS and RH

HI-98127 Advanced Pocket pH Meter HI-98128 Advanced 0.01 pH Pocket Meter HI-98311 Waterproof Conductivity Tester HI-98312 Waterproof Conductivity Tester HI-98129 Conductivity & pH Pocket Met
Range 0.0 to 14.0 pH
Resolution 0.1pH
Accuracy 0.1pH
Calibration Automatic at 1 or 2 points using memorised buffers
Buffers pH 4.01/7.01/10.01/6.86 & 9.18 are memorised
Compensation temperature compensated for between 0.0 and 60.0C
Dimensions 163 x 40 x 26mm; weight 85 gr
Spare Electrode HI-73127 electrode
Range 0.00 to 14.00pH
Resolution 0.01pH
Accuracy 0.05pH
Calibration automatic 1 or 2 point calibration
Buffers ph 4.01/7.01/10.01/6.86 & 9.18 are memorised
Compensation temperature compensated and displayed between 0.0 and 60.0C
Dimensions 163 x 40 x 26mm; weight 85 gr
Spare Electrode HI-73127 snap-in electrode

Range 0 to 3999uS/cm and 0 to 2000ppm and 0.0 to +60.0C
Resolution 1us/cm and 1ppm and 0.1C
Accuracy +/-2% scale and +/-2% scale and +/-0.5C
Calibration Automatic at 1 point
Size & Weight 163 x 40 x 26mm including electrode
Weight meter complete with electrode 85 grams
Batteries 4 x 1.5V, giving approx. 100 hours continuous use.
Range 0.00 to 20.00mS/cmand 0.00 to 10.00ppt and 0.0 to +60.0C
Resolution 0.01mS/cm and 0.01ppt and 0.1C
Accuracy +/-2% scale and +/-2% scale and +/-0.5C
Calibration Automatic at 1 point
Size&Weight 163x40x26mm includ electro
Weight meter comple with electrode 85 gr
Batteries 4 x 1.5V, giving approx. 100 hours continuous use.
Range 0.0 to 14.00pH 0 to 3999uS/cm and 0 to 2000ppm and 0.0 to +60.0C
Resol 0.01pH 1us/cm and 1 ppmand 0.1C
Accuracy +/-0.05pH +/-2% scale and +/-2% scale and +/-0.5C
Calibr Conductivity Automatic at 1 point
pH Automatic at 4.01, 6.86, 7.01, 9.18, 10.01 buffers
Size&Weight 163x40x26mm includ electro
Weight meter compl with electrode 85 gr
Batteries 4 x 1.5V, giving approx. 100 hours continuous use.
HI-98130 Conductivity & pH Pocket Met HI-98509 Pocket hand-held HI-151-00 Folding Probe Pocket Meter HI-98509-01 ChecktempDip HI-147-00 Checkfridge Thermometer
Range 0.00 to 14.00pH 0.00 to 20.00mS/cm and 0.00 to 10.00ppt  and 0.0 to +60.0C
Resol 0.01pH 0.01mS/cmand0.01ppt 0.1C
Accuracy +/-0.5pH +/-2% scale and +/-2% scale  and +/-0.5C
Calibration Conductivity calibration automatic at 1 point
pH calibration automatic at 4.01, 6.86, 7.01, 9.18, 10.01pH
Size&Weight 163x40x26mm includ electr
Range -20.0 to +120.0 C
Resolution 0.1C
Accuracy +/-0.3 C (-20 to 90C), +/-0.5C outside
Batteries 1 x 1.5V AAA size, 3000 hours use
Probe st/st 160mm x 3mm diameter with 1m cable
Size & Weight 106 x 58 x 19mm & 80 grams
Range -50 to +220 C
Resolution 0.1 C
Accuracy +/- 0.3 C - 20 to + 90 (+/- 0.4 % scale outside this range)
Battery 1 x AAA 1.5 V - giving 3000 hours (supplied)
Dimensions 165 x 50 x 20 mm (with probe folded) Probe - 115 x 3.2 mm
Weight 90 g
 
Range -20.0 to +100.0C
Resolution 0.1C
Accuracy +/-0.5C between the critical temperature of -20 to +50C
Probe stainless steel weighted probe on 3m cable included
Battery 1 x 1.5volt AAA battery included giving approximately 3000 hours use
Dimensions 106x58x19mm; 80grams
 
Range -20.0 to +120.0 C
Resolution 0.1C
Accuracy +/-0.3 C (-20 to 90C), +/-0.5C outside
Batteries 1 x 1.5V AAA battery giving approximately 3 years use.
Probe Stainless steel 40mm x 5mm sensor on a 1m silicon cable
Size & weight 92 x 36 x 28mm & 60 grams complete
 
HI-145-00 Pocket thermometer HI-145-20 Oil Fryer Thermometer HI-98201 ORP Pocket Tester HI-981408 Waterproof stick pH HI-98109 Skin pH meter
Range -50 to +220 C
Resolution 0.1 C
Accuracy +/-0.3 C
Probe 125mm x 5mm stainless steel stem
Battery 1 x 1.5volt AAA type giving 3,000 hours use
Dimensions 92 x 165 x 38mm; 65 grams
Range -50.0 to +220 C
Resolution 1 C (200 to 220 C)
Accuracy +/- 0.4 % FS (outside)
Probe Stainle steel, 300 x 5 mm (12 x 0.2")
Battery Life / Type 1 x 1.5 V AAA / 3000 hours of continuous use
Environm -10 to 50 C (14 to 122 F); 90 %
Dimensions 92 x 165 38 mm
Weight 65 g (2.4 oz)
  Range 0.0 to 14.0
Resolution 0.1 Ph
Acc (@20 degrees c)+/- 0.2 ph
Typical EMC Deviat +/- 0.2ph
Calibration Manual, 1 point from 4 to 7 ph
Probe HI-1219ph electrode, double junction, l:240 mm, DIN connector
Envir 0 to 50 deg c  100% RH
Dimens & Weight 86 x 94 x 33 mm; 150g
Range 0.00 to 14.00pH
Resolution 0.01pH
Accuracy +/-0.2pH
Calibration manual at 2 points
Compensation no temperature compensation on this model
Battery 2 x 1.4 volt giving 3000 hours use
Dimensions 66 x 50 x 25mm; 70 grams
HI-98110 Skin pH meter HI-98111 Piccolo pH meter HI-98112 Piccolo2 pH meter HI-98113 PiccoloPluspH/C met HI-98204 Watertest 4 in 1 meter
Range 0.00 to 14.00pH
Resolution 0.01pH
Accuracy +/-0.2pH
Calibration manual at 2 points
Compensation no temperature compensation on this model
Battery 2 x 1.4 volt giving 3000 hours use
Dimensions 66 x 50 x 25mm; 70 grams
Range 1.00 to 13.00 pH
Resolution 0.01pH
Accuracy +/-0.01pH
Calibration manual at 2 points
Compensation automatic temperature compensation between 0 and +70 C
Battery 3 x 1.4volt giving 100 hours use
Dimensions 194 x 29 x 15mm
Range 1.00 to 13.00 pH
Resolution 0.01pH
Accuracy +/-0.01pH
Calibration manual at 2 points
Compensation automatic temperature compensation between 0 and +70 C
Battery 3 x 1.4volt giving 100 hours use
Dimensions 194 x 29 x 15mm
Range 1.00 to 13.00 pH and 0 to 70 C
Resolution 0.01pH and 0.1C
Accuracy +/-0.01pH and +/-1 C
Calibration manual at 2 points
Compensation automatic temperature compensation between 0 and +70 C
Battery 3 x 1.4volt giving 100 hours use
Dimensions 194 x 29 x 15mm
Range 0.0 to 14.0pH 1000mV 0 to 1999uS/cm 0.0  to +60.0 C
Resolut  0.1pH 1mV 1uS/cm 0.1 C
Accuracy +/-0.2pH +/-5mV +/-2%FS +/-1C
Calibration Manual 2 points notapplicable Manual 1 point
Batteries 3 x 1.4V, 200 hours approx use
Size & weight 190mmx85mmx85mm&260gr
HI-98106 Pocket pH meter HI-98107 Pocket pH meter HI-98108 Pocket pH meter HI-98101 Pocket pH meter HI-98102 pocket pH meter
Range 0.0 to 14.0pH
Resolution 0.1pH
Accuracy +/-0.2pH
Calibration Manual single point
Compensation no temperature compensation
Battery 4 x 1.4volt giving 400 hours use
Dimensions 175 x 41 x 23mm; 78 grams
Range 0.0 to 14.0pH
Resolution 0.1pH
Accuracy +/-0.1pH
Calibration Manual single or two point
Compensation no temperature compensation
Battery 4 x 1.4volt giving 400 hours use
Dimensions 175 x 41 x 23mm; 78 grams
Range 0.0 to 14.0pH
Resolution 0.1pH
Accuracy +/-0.1pH
Calibration Manual single or two point
Compensation automatic between 0 and +50 C
Battery 4 x 1.4volt giving 100 hours use
Dimensions 175 x 41 x 23mm; 78 grams
Range 0.0 to 14.0 pH
Resolution 0.1 pH
Accuracy +/- 0.2 pH
Typical EMC Deviat +/- 0.2 pH
Calibr Manual 2 points through trimmers
pH electrode plastic body, double-junction, gel-filled
Battery Type / Life 2 x 1.4 V / approx 3000 hours contin use
Environm 0 to 50 C  RH 95%
Dimensions 200x28x 20 mm
Weight 46 g
Range 0.0 to 14.0 pH
Resolution 0.1 pH
Accuracy +/- 0.2 pH
Typical EMC Deviat +/- 0.2 pH
Calibr Manual 2 points through trimmers
pH electrode glass body, double-junction, gel-filled
Battery Type / Life 2 x 1.4 V / approx 3000 hours contin use
Environm 0 to 50 C  RH 95%
Dimensions 200x28x 20 mm
Weight 46 g
HI-98105 Lowcoststick pH meter HI-98104 Lowcoststick pH meter HI-98103 Lowcoststick pH meter HI-98501 Pocket Thermometer HI-98204 WaterpH/C/ORP Cond
Range 0.0 to 14.0 pH
Resolution 0.1 pH
Accuracy +/- 0.2 pH
Typical EMC Deviat +/- 0.1 pH
Calibration Manual 2 points through trim
pH electrode HI-1208 (included)
Battery Type / Life 2 x 1.4 V / approx 3000 hours contin use
Environm 0 to 50 C  RH 95 %
Dimensi 66 x 50 x 25 mm
Weight 70 g
Range 0.0 to 14.0 pH
Resolution 0.1 pH
Accuracy +/- 0.2 pH
Typical EMC Deviation +/- 0.1 pH
Calibration Manual 2 points through trim
pH electrode HI-1207 (included)
Battery Type / Life 2 x 1.4 V / approx 3000 hours continuous use
Environm 0 to 50 C  RH 95%
Dimensio 66 x 50 x 25 mm
Weight 70 g
Range 0.0 to 14.0 pH
Resolution 0.1 pH
Accuracy +/- 0.2 pH
Typical EMC Deviat +/- 0.1 pH
Calibration Manual 2 points through trim
pH electrode HI-1270 (included)
Battery Type / Life 2 x 1.4 V / approx 3000 hours contin use
Environm 0 to 50 C  RH 95 %
Dimensi 66 x 50 x 25 mm
Weight 70 g
Range -20.0 to +120.0 C
Resolution 0.1C
Accuracy +/-0.3 C (-20 to 90C), +/-0.5C outside
Batteries 1 x 1.4V, 3000 hours use
Probe st/st 105mm x 3mm diameter
Size & Weight 66 x 50 x 25mm & 50 grams
 
Range 0.0 to 14.0pH 1000mV 0 to 1999uS/cm 0.0  to +60.0 C
Resolution 0.1pH 1mV 1uS/cm 0.1 C
Accuracy +/-0.2pH +/-5mV +/-2%FS +/-1C
Calibration Manual 2 points notapplicable Manual 1 point
Batteries 3 x 1.4V, 200 hours approx use
Size & weight 190mm x 85mm x 85mm & 260 grams
HI-98308 Pure Water Tester HI-38309 Ultra Pure Water tester Dist 3 0 to 1999uS Dist 4 0 to 19.99mS Primo2TDS PocketTestATCwith
Range 0.1 to 99.9 uS/cm
Resolution 0.1 uS/cm
Accuracy +/-2 of Full scale
Calibration Manual 1 point through trimmer
Compensation Automatic from 10 to 40 C
Batteries 4 x 1.4V, 150 hours approx use
Size & weight 175mm x 41mm x 23mm & 80 grams
Range 0.000 to 1.999 S/cm
Resolution 0.001 S/cm
Accuracy (@ 20 C/ 68 F) +/- 2 % Full Scale
Typical EMC Deviation +/- 0.5 % Full Scale
Battery Type / Life 0 to 50 C (32 to 122); RH 95 %
Dimensions 175 x 40 x 20 mm (7.9 x 1.6 x 0.8)
Weight 122 g (4.3 oz)
Range 0 to 1999 uS/cm
Resolution 1 uS/cm
Accuracy +/-2% of full scale
Calibration single point at 1413uS/cm (HI-7031 solution)
Compensation automatic temperature compensation between 0 and +70 C
Battery 4 x 1.4volt giving 150 hours use
Dimensions 175 x 41 x 23mm; 78 grams
Range 0 to 19.99mS/cm
Resolution 0.01mS/cm
Accuracy +/-2% of full scale
Calibration single point at 5000uS/cm (HI-7039 solution)
Compensation automatic temperature compensation between 0 and +70 C
Battery 4 x 1.4volt giving 150 hours use
Dimensions 175 x 41 x 23mm; 78 grams
Range1999 ppm (mg/L);0.0to60 C
Resolution 1 ppm (mg/L); 0.1 C
Accuracy (20 C/68 F) +/- 2 % FS +/- 0.5 C
Calibration Automat at 1382 ppm
Temperature Compensation Automatic from 0 to 60 Cwith var of 2 % per degree C
Battery type / Life 2 x 1.4 V / Approximat 200 hours of continuous use.
Auto shut-off after 5 minutes non-use
Environm 0 to 50 C  RH 95 %
Dimensions / Weight 180 x 50 x 25 mm  80 g (2.9 oz)
HI-981410 Waterproof stick meter 0-10mS HI-981409 Waterproof Stick Conductivity
HI-981410
Range 0.00 to 10.00EC(Ms/cm)
HI-981409
Range 0 to 1999mg/l(ppm)

Conductivity and TDS Meters

HI-8033 Budget hand-held meter HI-98204 Water-test pH/C/ORP & Con HI-98321 Conductivity & TDS Sample HI-98322 Conductivity & TDS Sample  HI-9835 Conductivity & TDS meter
Range 0.00 to 20.00mS/cm 0.00 to 10.00ppt 0.0 to +60.0C
Resolution 0.01mS/cm 0.01ppt 0.1C
Accu 2% full scale 2% full scale +/-0.5C
Calibration Automatic single point using 1288mS/cm solution
Conversion Factor Adjustable from 0.45 to 1.00.
Battery 4 x 1.5volt AA type giving 100 hours use; auto-off after 8 minutes
Dimensi 120 x 53 x 81mm; 225g
Temperature
Range 0.0 to 14.0pH 1000mV 0 to 1999uS/cm 0.0 to +60.0 C
Resolution 0.1pH 1mV 1uS/cm 0.1 C
Accur  +/-0.2pH +/-5mV +/-2%FS +/-1C
Calibration Manual 2 points not applicable Manual 1 point not
Batteries 3 x 1.4V, 200 hours approx use
Size & weight 190mm x 85mm x 85mm & 260 grams
Range 0 to 3999uS/cm 0 to 2000ppm 0.0 to +60.0C
Resolution 1uS/cm 1ppm 0.1C
Accu 2% full scale 2% full scale +/-0.5C
Calibration Automatic single point using 1413uS/cm solut
Conversion Factor Adjustable from 0.45 to 1.00.
Battery 4 x 1.5volt AA type giving 100 hours use; auto-off after 8 minutes
Dimens 120 x 53 x 81mm; 225g
Range 0.00 to 20.00mS/cm 0.00 to 10.00ppt 0.0 to +60.0C
Resolution 0.01mS/cm 0.01ppt 0.1C
Accu 2% full scale 2% full scale +/-0.5C
Calibration Automatic single point using 1288mS/cm solution
Conversion Factor Adjustable from 0.45 to 1.00.
Battery 4 x 1.5volt AA type giving 100 hours use; auto-off after 8 min
Dimensions 120 x 53 x 81mm; 225grams
Range 30.0 to 299.9uS/cm with 0.1uS resolution
300 to 2999uS/cm with 1 uS resolution
3.00 to 29.99mS/cm with 0.01mS resolution
30.0 to 200mS/cm with up to 500mS/cm actual EC with 0.1mS resolution
Accuracy +/-1% of reading (0.05uS/cm or 1 digit whichever is greater)
HI-9810 Conductivity, TDS & pH Meter HI-9811 Conductivity, TDS & pH meter HI-9812 Conductivity, TDS & pH meter HI-9813 Conductivity & TDS & pH met HI-993310 Soil conductivity meter
Range 0.0 to 14.0pH 0 to 6000uSS/cm 0 to 3000mg/L  (ppm)
Resoluti 0.1 pH 10uS/cm 10mg/L
Accuracy +/- 0.2pH +/- 2% of scale +/-2% of scale
ConversFactor Set at 0.5 ppm = 1 S/cm
Calibration Manual 1 point through trimmer for all paramete
Compensation Automatic from 0 to 50C
Probe HI-1285 pH/conductivity/TDS/C probe (included)
Battery Type / Life 1 x 9volt PP3 giving approx. 150 hours contin
Dimensio185 x 82 x 45 mm; 520 g
Range 0.0 to 14.0 pH; 0.00 to 6.00 mS/cm; 0.00 to 3.0g/L ppt
Resolution 0.1 pH; 0.01 mS/cm; 0.01 g/L
Accuracy (@ 20 C/ 68 F) +/- 0.2 pH; +/- 2 % FS
Typical EMC Dev +/- 0.1 pH; +/- 2 %FS
EC/TDS Conv Factor 0.5 ppm = 1 S/cm
Calibration Manual 1 point through trimmer for all param
Probe HI-7632 EC probe
Battery Type / Life 1 x 9 V / approx 150 hours continuous
Envir 0 to 50 C  RH 95 %
Dimen 185 x 82 x 45 mm
Weight 520 g (1.1 lb)
Range 0.0 to 14.0pH
0 to 1990uS/cm
0 to 1990mg/l
Resolution 0.1pH, 10uS/cm, 10mg/l
Accuracy +/-0.2pH, +/-2% full scale, +/- 2% full scale
Calibration Manual single point via trimmer for all parameters
Compensation Automatic from 0 to +50 C with differential of 2% per degree C
(conductivity & TDS only)
Battery 1 x 9V for 150 hours use approx
Size & Weight 185 x 82 x 45mm & 520 grams
Range pH 0.0 to 14.0, EC 0.00 to 4.00, TDS 0 to 1999 ppm
TDS Ratio 0.65 ppm = 1 uS/cm
Resolution pH 0.1, EC 0.01, TDS 1 ppm
Accur pH +/-0.2, EC +/-2%, TDS +/-2%.
Typical EMC Deviation pH +/-0.2, EC +/-2% Full Scale, TDS +/-2% Full Scale.
Calibration Manual 1 point through trimmer for all parameters
Probe HI-1285 pH/EC/TDS probe with DIN connector.
Battery Type/Life 1 x 9V / 150 hours approx. continuous use.
Dimensions 180 x 82 x 45mm
Weight 520g
Rang0.00 to19.99mSand0.0to 1.0 g/l salt
Resolution 0.01mS and 0.1g
Accuracy +/-2% of full scale
Compensation automatic temperature compensation between 0 and +50C
Probe(s) HI-76305 amperometric stainless steel probe with 1m cable
Battery 1 x 9volt PP3 giving 100 hours of continuous use
Dimensions 185 x 82 x 45mm
Weight 355 grams
HI-8633 Hand-held meter without ATC HI-8733 Hand-held meter with ATC HI-9033 Waterproof Conductivity met HI-991300 Waterproof Conductivity & TDS HI-991301 Waterproof conductivity & TDS
Range 0.0 to 199.9uS/cm 0 to1999uS/cm
0.00 to 19.99mS/cm 0.0 to 199.9mS/cm
Resolution 0.1uS/cm 1uS/cm
0.01mS/cm 0.1mS/cm
Accuracy +/-1% of Full Scale
Calib Manual single point via trim
Compensation HI-8633: Manual from +10 to +40C with adjustable differential of 2.0% per C
Battery 1 x 9V for 100 hours use
Size & Weight 185 x 82 x 45mm & 355 gr
Range 0.0 to 199.9uS/cm 0 to 1999uS/cm
0.00 to 19.99mS/cm 0.0 to 199.9mS/cm
Resolution 0.1uS/cm 1uS/cm
0.01mS/cm 0.1mS/cm
Accuracy +/-1% of Full Scale
Compensation Automatic from 0 to +50 C with adjustable differential of 0 to 2.5% per C
Battery 1 x 9V for 100 hours use
Size & Weight 185 x 82 x 45mm & 355 gr
Range 0.0 to 199.9 uS/cm 0 to 1999 uS/cm 0.00 to 19.99 mS/cm 0.0 to 199.9
mS/cm
Resolution 0.1 uS/cm 1 uS/cm 0.01 mS/cm 0.1 mS/cm
Accuracy +/-1% Full scale
Calibration Manual single point through trimmer
Compensation Automatic from10to 40 C
Size & Weight 196mm x 80mm x 60mm & 425 grams
Range 0.00 to 14.00 pH, 0.0 to 60.0-degree c, 0 to 3999uS/cm (EC),
and 0 to 2000ppm (TDS)
Resolution 0.01ph, 0.1degree c, 1uS/cm, 1ppm.
Accuracy +/-0.01 pH, +/-0.5 degree c, +/-2%Full scales (EC/TDS)
PH calibration automatic
EC/TDS calibration automatic
Probe HI-1288 pH/EC/TDS probe with build it temp sensor DIN
connector.
Dimensions 143 x 80 x 38mm
Weight 320g
Range 0.00 to 14.00 pH, 0.0 to 60.0-degree c,
0.00 to 19.99mS/cm (EC), and 0.00 to 10.00ppt (TDS)
Resolution 0.01 pH, 0.1 degree c, 0.01mS/cm, 0.01ppt
Accuracy +/-0.01ph, +/-0.5 degree c, +/-2%full scales (EC/TDS)
PH calibration automatic
EC/TDS calibration automatic
Probe HI-1288 pH/EC/TDS probe with built in temperature sensor with DIN connector.
Dimensions 143 x 80 x 38mm
Weight 320g
HI-9932 Multi-parameter bench meter HI-933300 Printing & Logging meter HI-933301 Printing & Logging meter EC214 Bench meter EC215 Bench meter with ATC
Range Conductivity - 0.0 to 399.9 / 399 to 3999uS/cm;
3.99 to 39.99 / 39.9 to 99.9mS/cm
Fertiliser - 0.00 to 39.99g/l
Sea Water - 0.0 to 130.0%
TDS - 0.0 to 199.9mg/l, 0 to 1999mg/l 0.00 to 19.99g/l
Temperature - 0.0 to +50.0C
Resolution 0.1uS/cm, 0.01g/l, 0.1%, 0.1mg/l, 0.1C
Accuracy 1% of full scale across all four ranges, 0.5C
Calib Autom set point at 84uS, 1,413uS, 12,88mS and 80.0mS
Compensation Selectable autom or manual from 0 to +50 C
Range 0.0 to 150.0 uS/cm
50 to 1500 uS/cm
1.50 to 15.00 mS/cm
15.0 to 199.9 mS/cm
0.0 to 60.0 C
Resolution 0.1 uS   1 uS/cm  0.01 mS/cm
0.1 mS/cm     0.1 C
Accuracy +/-1% Full Scale
Calibration Automatic 1, 2, 3, 4, or 5 points at 0,84,1413,12880, 80000 uS/cm
Range 0.0 to 150.0 uS/cm
50 to 1500 uS/cm
1.50 to 15.00 mS/cm
15.0 to 199.9 mS/cm
0.0 to 60.0 C
Resolution 0.1 uS   1 uS/cm  0.01 mS/cm
0.1 mS/cm     0.1 C
Accuracy +/-1% Full Scale
Calibration Automatic
EC214
Range 0.0 to 199.9 uS/cm, 0 to 1999 uS/cm, 0.00 to 19.99 mS/cm,0.0 to 1999.9
mS/cm
Resolution 0.1 uS/cm, 1 uS/cm, 0.01 mS/cm, 0.1 mS/cm
Accuracy +/- 1% F.S (excl probe error)
Calibration Manual 1 point with knob
Compensation Manual form 0 to 50 degree c
Range 0.0 to 199.9 uS/cm, 0 to 1999 uS/cm, 0.00 to 19.99 mS/cm, 0.0 to1999.9
mS/cm
Resolution 0.1 uS/cm, 1 uS/cm, 0.01 mS/cm, 0.1 mS/cm
Accuracy +/- 1% F.S (excl probe error)
Compensation Automatic from 0 to 50 degree c with an adjusta B from 0 to 2.5% per degree c
Probe HI-96303 conductivity probe with platinum 4-ring, temp sensor, cable 1m
Power supply 12VDC power adapter

Dataloggers for EC, pH, C, %RH, DO

HI-91410 Printing & Logging D.O. mete HI-933300 Printing & Logging meter HI-933301 Printing & Logging meter HI-91610 Logging Hygrometer HI-98230 pH/C printing & logging
Range 0.00 to 19.99mg/l; 0.0 to 50.0 C
Resolution 0.01mg/l; 0.1 C
Accuracy 1.5% of full scale; +/-0.5 C
Calibration Automatic at 100% with zero check
Compensation Automatic from 0 to +50 C
Batteries 4 x 1.5V AA
Size & Weight 220 x 82 x 66mm & 510 grams including the sensor
Range 0.0 to 150.0 uS/cm
50 to 1500 uS/cm
1.50 to 15.00 mS/cm
15.0 to 199.9 mS/cm 0.0 to 60.0 C
Resolution 0.1 uS 1 uS/cm  0.01 mS/cm
0.1 mS/cm   0.1 C
Accuracy +/-1% Full Scale
Calibration Automatic 1, 2, 3, 4, or 5 points at 0,84,1413,12880, 80000 uS/cm
Compensation Automatic from 0 to60 C
Range 0.0 to 150.0 uS/cm
50 to 1500 uS/cm     1.50 to 15.00 mS/cm
15.0 to 199.9 mS/cm     0.0 to 60.0 C
Resolution 0.1 uS    1 uS/cm 0.01 mS/cm
0.1 mS/cm    0.1 C
Accuracy +/-1% Full Scale
Calibration Automatic 1, 2, 3, 4, or 5 points at 0,84,1413,12880, 80000 uS/cm
Compensat Autom from 0 to 60 C
Range 5.0 to 95.0% RH; -20.0 to +60.0C
Resolution 0.1% RH; 0.1C
Accuracy 2% RH full scale, +/-0.4C
Calibration Supplied factory calibrated
Print/ log intervals 1,2,5,10,15,30,60,120,180 mins
Power supply 4 x 1.5 V AA batteries plus power socket for 12VDC supply
Size & Weight 220 x 82 x 66mm & 500 grams
Range -4.00 to 19.99 pH -10.0 to 120.0 degree c
Resolution 0.01 pH 0.1 degree c
Accuracy +/- 0.01ph +/-0.5 degree c +/-1 degree c (outside)
Typical EMC Deviation +/-0.03ph +/-0.8
Calibration pH automatic
Compensation automatic -10 to 120 C
Dimensions 220 x 82 x 66mm
Weight 500g
HI-98240 mV/pH/C printing & loggin HI-98810 1-channel log & print meter HI-98840 4-channel log & print meter HI-98801 1-channel log & print K-type HI-98804 4-channel print & log K-type
Range -4.00 to 19.99 pH -10.0 to 120.0 degree c
+/-400.0mV(ise) +/-22000mV
Resol  0.01 pH 0.1 degree c, 0.1mV 1mV
Accuracy +/-0.01 pH +/-0.5 degree +/-0.5Mv +/-2Mv
Calibration Automatic 2 point at 0, 350mV or 3 point at 0, 350, 1900 mV.
Compensat Automatic from -10 to 120 C
pH electrode HI-1618d DIN connector
Dimensions 220 x 82 x 66mm
Weight 500g
RANGE -50.0 to 150.0C; -55.0 to 300.0F
RESOLUTION 0.1C (-30 to 130C); 0.2C (outside); 0.1F (-18 to 225F);
0.2F (225 to 260); 0.3F(outside)
ACCURACY +/- 0.4C (-20 to 120C); +/-0.7C (outside); +/-0.8F (-4 to
248F); 1.3F (outside) for one year,
excluding probe error
TYPICAL EMC DEVIATION +/- 0.4C; +/-0.8F
CHANNELS 1 Channel
RANGE -50.0 to 150.0C; -55.0 to 300.0F
RESOLUTION 0.1C (-30 to 130C); 0.2C (outside); 0.1F (-18 to 225F);
0.2F (225 to 260); 0.3F(outside)
ACCURACY +/- 0.4C (-20 to 120C); +/-0.7C (outside); +/-0.8F (-4 to
248F); 1.3F (outside) for one year,
excluding probe error
TYPICAL EMC DEVIATION +/- 0.4C; +/-0.8F
CHANNELS 4 Channel
RANGE K: -200.0 TO + 999.9C; 1000 to 1370C; -300.0 to 999.9F; 1000 to
2500F
J: -200.0 to 760.0C; -300.0 to 999.9F; 1000 to 1400F
T: -200.0 to 400.0C; -300.0 to 750F
RESOLUTION K: 0.1 C(-99.9 to 999.9C); 1C (1000 to 1370C);
0.2C (-200.0 to -100.0C)
ACCURACY 5C (-200.0 to 999.9C); +/-1C (Outside); +/-1F
RANGE K: -200.0 TO + 999.9C; 1000 to 1370C; -300.0 to 999.9F; 1000 to
2500F
J: -200.0 to 760.0C; -300.0 to 999.9F; 1000 to 1400F
T: -200.0 to 400.0C; -300.0 to 750F
RESOLUTION K: 0.1 C(-99.9 to 999.9C); 1C (1000 to 1370C);
0.2C (-200.0 to -100.0C)
ACCURACY 5C (-200.0 to 999.9C); +/-1C (Outside); +/-1F
HI-955301 1-channel print & log PT100 HI-955302 2-channel print & log PT100 HI-140 Compact Waterproof Datalogg HI-141AH Datalogger -40 to +80C HI-141BH Datalogger -40 to +125C
Range -200.0 to 850.0 C
Resolution 0.1 C
Accuracy +/- 0.1 C +/-0.1% of reading
Channels 1
Prin intervals 1,2,5,10,30,60,120,180 min
Power 4 x 1.5V AA batteries, auto shut off after 5 mins non-use, power
socket for 12VDC
Size&weight 220mmx82mmx66mm 500gr
Range -200.0 to 850.0 C
Resolution 0.1 C
Accuracy +/- 0.1 C +/-0.1% of reading
Channels 2
Print intervals 1,2,5,10,30,60,120,180 min
Power 4 x 1.5V AA batteries, auto shut off after 5 mins non-use, power
socket for 12VDC
Size & weight 220mm x 82mm x 66mm & 500 grams
Dimensions (dia x h)mm: 86 x 40
Memory 7600 samples
Recording interval 1min to 24 hours with delayed start time option
Alarm user can set high and low limits
Range -40.0 to +80.0C
Resolution 0.1C up to 100C, and then 0.2C above 100C
Accuracy +/-0.5 between -40.o to 0.0C
+/-0.4 between 0.0 to +70C
+/-0.5 between +70 and +100C
+/-1.0C for temperatures higher than +100C
Sensor 1 internal sensor
Range -40.0 to +125.0C
Resolution 0.1C up to 100C, and then 0.2C above 100C
Accuracy +/-0.5 between -40.o to 0.0C
+/-0.4 between 0.0 to +70C
+/-0.5 between +70 and +100C
+/-1.0C for temperat higher than +100C
Sensor 1 external stainless steel sensor on 1m cable
HI-141CH LCD Datalogger -20 to +70C HI-141DH LCD Datalogg -40 to +125C HI-141EH 2 Channel Datalog -40to+80C HI-141FH 2 Channel Datalo -40to+125C HI-141GH LCD 2 Channel Datal -20+70
Range -40.0 to +70.0C (and -40 to +175F)
Resolution 0.1C up to 100C, and then 0.2C above 100C
Accuracy +/-0.5 between -40.o to 0.0C
+/-0.4 between 0.0 to +70C
+/-0.5 between +70 and +100C
+/-1.0C for temperatures higher than +100C
Sensor 1 internal sensor
Range -40.0 to +70.0C (and -40 to +175F) using the internal sensor
-40.0 to +125.0C (and -40 to +257F) using the external sensor
Resolution 0.1C up to 100C, and then 0.2C above 100C
Acc +/-0.5 between -40.o to 0.0C
+/-0.4 between 0.0 to +70C
+/-0.5 between +70 and +100C
+/-1.0C for temperat  higher than +100C
Sensors 1 internal sensor
Range -40.0 to +70.0C (and -40 to +175F) using the internal sensor
-40.0 to +125.0C (and -40 to +257F) using the external sensor
Resolution 0.1C up to 100C, and then 0.2C above 100C
Accu+/-0.5 between -40.o to 0.0C
+/-0.4 between 0.0 to +70C
+/-0.5 between +70 and +100C
+/-1.0C for temperat higher than +100C
Sensors 1 internal sensor
Range -40.0 to +125.0C (and -40 to +257F)
Resolution 0.1C up to 100C, and then 0.2C above 100C
Accuracy +/-0.5 between -40.o to 0.0C
+/-0.4 between 0.0 to +70C
+/-0.5 between +70 and +100C
+/-1.0C for temperatures higher than +100C
Sensors 2 external stainless steel sensors on 1m cable
Range -40.0 to +70.0C (and -40 to +175F) using the internal sensor
-40.0 to +125.0C (and -40 to +257F) using the external sensor
Resolution 0.1C up to 100C, and then 0.2C above 100C
Accu+/-0.5 between -40.o to 0.0C
+/-0.4 between 0.0 to +70C
+/-0.5 between +70 and +100C
+/-1.0C for temperat  higher than +100C
Sensors 1 internal sensor

Food Thermometers and Probes

HI-98501 Pocket Thermometer HI-98509 Pocket hand-held HI-98509-01 ChecktempDip HI-147-00 Checkfridge Therm HI-9041 Classic hand-held
Range -20.0 to +120.0 C
Resolution 0.1C
Accuracy +/-0.3 C (-20 to 90C), +/-0.5C outside
Batteries 1 x 1.4V, 3000 hours use
Probe st/st 105mm x 3mm diameter
Size & Weight 66 x 50 x 25mm & 50 grams
Range -20.0 to +120.0 C
Resolution 0.1C
Accuracy +/-0.3 C (-20 to 90C), +/-0.5C outside
Batteries 1 x 1.5V AAA size, 3000 hours use
Probe st/st 160mm x 3mm diameter with 1m cable
Size & Weight 106 x 58 x 19mm & 80 gr
Range -20.0 to +100.0C
Resolution 0.1C
Accuracy +/-0.5C between the critical temp of -20 to +50C
Probe stainless steel weighted probe on 3m cable included
Battery 1 x 1.5volt AAA battery included giving approximately 3000 hours use
Dimens 106x58x19mm; 80gr
Range -20.0 to +120.0 C
Resolution 0.1C
Accuracy +/-0.3 C (-20 to 90C), +/-0.5C
Batteries 1 x 1.5V AAA battery giving approx 3 years use.
Probe Stainle steel 40mm x 5mm sensor on a 1m silicon cable
Size & weight 92 x 36 x 28mm & 60 grams complete
Range -50.0 to +150.0C
Resolution 0.1C
Accuracy +/-0.4C full range
Size & Weight 180 x 82 x 49mm & 280 grams

 
HI-145-00 Pocket thermometer HI-145-20 Oil Fryer Thermom HI-151-00FoldingProbe Pocket HI-8751BudgetThermo c/w pr HI-9061 Waterproof Model
Range -50 to +220 C
Resolution 0.1 C
Accuracy +/-0.3 C
Probe 125mm x 5mm stainless steel stem
Battery 1 x 1.5volt AAA type giving 3,000 hours use
Dimensions 92 x 165 x 38mm; 65 grams
Range -50.0 to +220 C
Resolut 1 C (200 to 220 C)
Accuracy +/- 0.4 % FS
Probe Stainl steel300 x 5mm
Battery Life / Type 1 x 1.5 V AAA / 3000 hours of continuous use
Environ-10 to 50 C (14 to 122 F); 90 %
Dimensions 92 x 165 38 mm
Weight 65 g (2.4 oz)
Range -50 to +220 C
Resolution 0.1 C
Accuracy +/- 0.3 C - 20 to + 90 (+/- 0.4 % scale outside this range)
Battery 1 x AAA 1.5 V - giving 3000 hours (supplied)
Dimensions 165 x 50 x 20 mm (with probe folded) Probe - 115 x 3.2 mm
Weight 90 g
HI-8751
Range -40.0 to +150.0C
Resolution 0.1 C
Accuracy +/-0.5 C full range
Size & Weight 180 x 83 x 40mm & 240 gram
Range -50.0 to 150.0C
Resolution 0.1C
Accuracy +/-0.4 C
Size & weight 196mm x 80mm x 60mm & 425 grams
HI-935007 Thermocouple Prob HI-93502 Lumberg Probe HI-93503 Compact Series HI-99556-00 Infrared & Probe HI-99550-00 Infrared Only
Range - 50 to 950 C
Resolution 0.1 C
Accuracy +/- 0.2 % FS for 1 year, excluding probe error
Probe HI-766C (fixed)
Battery Life / Type 1 x 9 V / approx. 500 hours continuous use
Environment 0 to 50 C (32 to 122 F)
Dimensions 143 x 80 x 38 mm (5.6 x 3.1 x 1.5 ")
Weight 320 g (11.3 oz)
Range -20.0 to +120.0 C
Resolution 0.1 C
Accuracy +/- 0.4 C across the whole range
Socket Lumberg type - 6 pin, screw lock
Battery Type / Life 1 x 9 V / approx 1000 hours continuous use
Environment 0 to 50 C; RH 95 %
Dimensions 80 x 36 x 142 mm
Weight 200 g
Range -50.0 to +150.0(C
Resolution 0.1(C
Accuracy (0.4(C (-20 to 80C) & (0.3% (outside)
Battery 1 x 9V PP3 size approx 1000 hours life
Size & Weight 140 x 78 x 32mm; 140 grams

RANGE in infrared mode -10 to300C;
With Probe connec: -40 to 150C
Resolution IR: 1C  Probe: 0.1C
Accuracy IR: +/- 2% read or 2C
Probe: +/- 0.5C (-20 to 120C) & +/-0.5 C + 1% reading (outside)
RESPONSE TIME 1 second or less
IR
COEFFIEICNT 3:1 (ratio of distance to diameter of target)
BATTERY 1 x 9V
ENVIRONMENT 0 to 50 C
DIMENSIONS 143 x 80 x 39 mm
WEIGHT 320 g (11.3 oz)

RANGE -10 TO 300C
RESOLUTION 1C
Accuracy +/-2 % of reading or +/-2C (whichever greater)
OPTIC COEFFICIENT 3:1 (ratio of distance to diameter of target)
BATTERY TYPE 1 x 9V
ENVIRONMENT 0 to 50C; RH. 95%
DIMENSIONS 143 x 80 x 38 mm (5.6 x 3.2 x 1.5")
WEIGHT 320 g (11.3 oz)
HI-98810 printing & logging HI-98840 printing & logging HI-148-00 Temperature Indicat HI-150-00 Temperature Indicat HI-140 Datalogger
RANGE -50.0 to 150.0C; -55.0 to300.0F
RESOLUTION 0.1C (-30 to 130C); 0.2C (outside); 0.1F (-18 to 225F);
0.2F (225 to 260); 0.3F(outside)
ACCURACY +/- 0.4C (-20 to 120C); +/-0.7C (outside); +/-0.8F (-4 to 248F); 1.3F for one year, excluding probe err
TYPICAL EMC DEVIATION +/- 0.4C; +/-0.8F
CHANNELS 1 Channel
RANGE -50.0 to 150.0C; -55.0 to 300.0F
RESOLUTION 0.1C (-30 to 130C); 0.2C (outside); 0.1F (-18 to 225F);
0.2F (225 to 260); 0.3
ACCURACY +/- 0.4C (-20 to 120C); +/-0.7C (outside); +/-0.8F (-4 to
248F); 1.3F  for one year,
excluding probe error
TYPICAL EMC DEVIATION +/- 0.4C; +/-0.8F
CHANNELS 4 Channel
RANGE -20 to 60.0C
RESOLUTION 0.1C
ACCURACY +/-0.5C
SETPOINT Selectable from 0.0 to 50.0C
ALARM LED blinks when measured temperature is higher than the setpoint
POWER SUPPLY 12 VDC external power adapter
ENVIRONMENT -20 to 60C; RH 100%
DIMENSIONS 86 x 94 x 33 mm
WEIGHT 150 g (5.2 oz)
RANGE -20.0 to 60.0C
RESOLUTION 0.1C
ACCURACY +/-0.5C
SETPOINT Selecta from 0.0 to 50.0C
POWER SUPPLY 12 VDC external power adapter (included)
ENVIRONM -20 to 60C; RH 100%
DIMENSIONS 86 x 94 x 33 mm
WEIGHT 150 g (5.2 oz)
Dimensions (dia x h)mm: 86 x 40
Memory 7600 samples
Recording interval 1min to 24 hours with delayed start time option
Alarm user can set high and low limits
 
HI-765PW Penetration Probe HI-765W Air Wire Probe HI-765FS Food Simulant Probe HI-762PW/LUMLumb Penet HI-765BPG Between Pack Probe
Our general purpose penetration stainless steel probe can be used to take air, liquid and
between pack temperatures in addition to destructive testing on food products. This probe is compatible with the HI-8751, HI-9041, HI-9061and HI-93503 Pronto food therm
This air wire probe is fexible and small, making it the ideal choice if you wish to take a measurement in a fard to reach place. or wish for fast air response times. Suitable for use with
the HI-8751, HI-9041, HI-9061 and HI-93503 Pronto thermometer
Suitable for use with the HI-8751, HI-9041, HI-9061 and HI-93503 Pronto Hanna thermometers.

 
Hanna Lumberg probes are designed to be compatible with any make of Lumberg
thermometer. Within the Hanna range they are for use with the HI-93502 thermometer
The HI-765BPG is a between pack probe with a 1m cable. Manufactured from a very robust
material which is highly resistant to tearing, the HI-765BPG probe is designed to provide
between pack temperatures in heavy use environments.

Colorimeters - Multi-parameter

HI-93710 Chlorine & pH meter HI-93724 CyanurichAcid&pH HI-93725 Tot Hardness&pH HI-93741 TotHardness&Iron C101 Br, Cl, CYS, Fe, I & pH meter
pH ; Free ; Total chlorine
Range 5.9 to 8.5 pH ; 0.00 to 2.50 mg/L ; 0.00 to 3.50 mg/L
Resolution 0.1 pH ; 0.01 mg/L
Accuracy (@20 C/68 F) +/- 0.03 mg/L +/- 3 % of reading ; +/- 0.1 pH
Typical EMC Deviation +/- 0.02 mg/L ; +/- 0.2 pH
LightsourceLightEmittingDiode 555 nm
Light detector Silicon photocell
Battery type / Life 1 x 9 V / Approxim 40 hours of continuous use. Auto shut-off after 10 minutes non-use
Envir 0 to 50 C (32 to 122 F); RH 95 %
Dimensions / Weight 180 x 83 x 46 mm (7.1 x 3.3 1.8") / 290 g
Cyanuric acid ; pH
Range 0 to 80 mg/L ; 5.9 to 8.5 pH
Resolution 1 mg/L ; 0.1 pH
Accuracy (@20 C/68 F) +/- 1 mg/L +/- 15 % of reading ; +/- 0.1 pH
Typical EMC Deviation +/- 0.1 mg/L
Light source Light Emitting Diode555 nm
Light detector Silicon photocell Battery type / Life 1 x 9 V Approximately 40 hours of continuous use. Auto shut-off after 10 minutes non-use
Environ 0 to50 C RH 95 %
Dim / Weight 180 x 83 x 46 mm 290 g
Total hardness ; pH
Range 0.00 to 4.70 mg/L ; 5.9 to 8.5 pH
Resolution 0.01 mg/L ; 0.1 pH
Accuracy (@20 C/68 F) +/- 0.11 mg/L +/- 5 % of reading ; +/- 0.1 pH
Typical EMC Deviation +/- 0.02 mg/L ; +/- 0.1 pH
Light sourceLight Emitting Diod 555 nm
Light detector Silicon photocell
Battery type / Life 1 x 9 V / Approximat 40 hours of continuous use. Auto shut-off after 10 minnon-use
Enviro 0 to 50 C  RH 95 %
Dimensions / Weight 180 x 83 x 46 mm 290 g
Total hardness ; Iron LR
Range 0.00 to 4.70 mg/L ; 0 to 400 g/L
Resolution 0.01 mg/L ; 1 g/L
Accuracy (@20 C/68 F) +/- 0.11 mg/L +/- 5 % of reading ; +/- 10 g/L +/- 8 % of reading
Typical EMC Deviation +/- 0.02 mg/L ; +/- 1 g/L
Light sourceLight Emitting Diod 555 nm
Light detector Silicon photocell
Battery type / Life 1 x 9 V / Approxim 40 hours of continuous use. Auto shut-off after 10min non-use
Enviro 0 to 50 C (32 to 122 F); RH 95 %
Dimensions / Weight 180 x 83 x 46 mm (7.1 x 3.3 1.8") / 290 g
Br; Cl; CYS; Fe; I; pH
Range 0.00 to 8.00 mg/L; 0.00 to 2.50 mg/L; 0.00 to 3.50 mg/L; 0 to 80mg/L; 0 to 400 (g/L;
0.0 to 12.5 mg/L; 5.9 to 8.5 pH
Resolution 0.01 mg/L; 0.01 mg/L; 1 mg/L; 1 (g/L; 0.1 mg/L;
0.1 pH
Accuracy +/- 0.8 mg/L +/- 3 %; +/- 0.03 mg/L +/- 3 %;+/-1 mg/L +/- 15%; +/- 10 (g/L
+/- 8 %; +/- 0.1 mg/L +/- 5 % of reading; +/- 0.1pH
Typical EMC Deviation +/- 0.01 mg/L; +/- 0.01 mg/L; +/- 1 (g/L; +/- 1 (g/L;
+/- 0.1 mg/L; +/- 0/1 pH
HI-93742 Iron & Manganese meter HI-93743 Iron & pH meter HI-93744 TotalHardness,Iron & pH met C104 Chlorine,Cyanuric Acid & pH met C203 Multi-parameter Aquaculture met
Iron (Fe) ; Manganese (Mn)
Range 0 to 400 g/L ; 0 to 300 g/L
Resolution 1 g/L
Accuracy (@20 C/68 F) +/- 10 g/L +/- 8 % of reading ; +/- 2 g/L +/- 3 % reading
Typical EMC Deviation +/- 1 g/L
Light source Light Emitt Diod 555 nm
Light life Life of the instrument
Light detector Silicon photocell
Battery type / Life 1 x 9 V / Approxi 40 hours of continuous use.
Auto shut-off after 10 minutes non-use
Envir 0 to 50 C (32 to 122 F); RH 95 %
 
Iron (Fe) ; pH
Range 0 to 400 g/L; 5.9 to 8.5 pH
Resolution 1 g/L; 0.1 pH
Accuracy (@20 C/68 F) +/- 10 g/L +/- 8 % of reading; +/- 0.1 pH
Typical EMC Deviation +/- 1 g/L; +/- 0.1 pH
Light source Light Emitting Diode 555 nm
Light life Life of the instrument
Light detector Silicon photocell
Battery type / Life 1 x 9 V / Approximately 40 hours of continuous use.
Auto shut-off after 10 minutes non-use
Envir  0 to 50 C RH 95 %
Iron; Hardness; pH
Range 0 to 400 g/L ; 0.00 to 4.70 mg/L ; 5.9 to 8.5 pH
Resolution 1 g/L ; 0.01 mg/L ; 0.1 pH
Accuracy (@20 C/68 F) +/- 10 g/L +/- 8 % of reading ; +/- 0.11 mg/L +/- 5 % of
reading; +/-  0.1 pH
Typ EMC Deviation +/- 1 g/L ; +/- 0.02 mg/L ; +/- 0.1 pH
Light source Light Emitt Diod 555 nm
Light life Life of the instrument
Light detector Siliconphotocell
Battery type / Life 1 x 9 V / Approximat 40 hours of continuous use.
Auto shut-off after 10 minutes non-use
Envir  0 to 50 C  RH 95 %
Free and tot chlorine;cyanuric acid ; pH
Range 0 to 2.50 mg/L ; 0.00 to 3.50 mg/L ; 0 to 80 mg/L ; 5.9 to 8.5 pH
Resolution 0.01 mg/L ; 1 mg/L ; 0.1 pH
Accuracy (@20 C/68 F) +/-0.03 mg/L +/- 3% of reading; +/- 1 mg/L+/-15 %of reading;+/-0.1pH
Typical EMC Deviation +/- 0.01 mg/L ; +/- 1mg/L ; +/- 0.1 pH
Light source Light Emitt  Diode 555 nm
Light life Life of the instrument
Light detector Silicon photocell
Battery type / Life 1 x 9 V / Approx 40 hours of continuse.
Auto shut-off after 10 minutes non-use
Envir 0 to 50 C  RH 95 %
Typical Use Bench/Portable
Principle of Operation Interference Filter Photometer, with four different wavelengths
Light Source Tungsten Subminiature Lamp 5 V - 0.115
Bulb Life Entire life of the instrument
Central Wavelengths 420 nm / 525 nm / 575 nm / 610 nm / 460 nm
Wavelength Accuracy +/- 2nm (full scale)
C205 for Boiler and Cooling Towers C211 for Chemical Industry C209 for Education needs C206 for Environmental testing C207 for Industrial Waste Water
Typical Use Bench/Portable
Principle of Operation Interference Filter Photometer, with four different wavelengths
Light Source Tungsten Subminiature Lamp 5 V - 0.115
Bulb Life Entire life of the instrument
Cent Wavelengths 420 nm / 525 nm / 575 nm / 610 nm / 460 nm
Wavelength Accuracy +/- 2nm (full scale)
Typical Use Bench/Portable
Principle of Operation Interference Filter Photometer, with four different wavelengths
Light Source Tungsten Submini Lamp 5 V - 0.115
Bulb Life Entire life of the instrument
Central Wavelengths 420 nm / 525 nm / 575 nm / 610 nm / 460 nm
Wavelength Accuracy +/- 2nm (full scale)
Typical Use Bench/Portable
Principle of Operation Interference Filter Photometer, with four different wavelengths
Light Source Tungsten Subminiature Lamp 5 V - 0.115
Bulb Life Entire life of the instrument
CentWavelengths 420 nm / 525 nm / 575 nm / 610 nm / 460 nm
Wavelength Accuracy +/- 2nm (full scale)
Spectral Bandwidth Typical 12 nm
Typical Use Bench/Portable
Principle of Operation Interference Filter Photometer, with four different wavelengths
Light Source Tungsten Subminiature Lamp 5 V - 0.115
Bulb Life Entire life of the instrument
Cent Wavelengths 420 nm / 525 nm / 575 nm / 610 nm / 460 nm
Wavelength Accuracy +/- 2nm (full scale)
Spectral Bandwidth Typical 12 nm
Typical Use Bench/Portable
Principle of Operation Interference Filter Photometer, with four different wavelengths
Light Source Tungsten Subminiature Lamp 5 V - 0.115
Bulb Life Entire life of the instrument
Cent Wavelengths 420 nm / 525 nm / 575 nm / 610 nm / 460 nm
Wavelength Accuracy +/- 2nm (full scale)
Spectral Bandwidth Typical 12 nm
C208 for Water Conditioning control C215 for Fertilizer and Nutrient testing C213 for Drinking Water monitoring C212 for Power Plants C210 for Pulp and Paper Mills
Typical Use Bench/Portable
Principle of Operation Interference Filter Photometer, with four different wavelengths
Light Source Tungsten Subminiature Lamp 5 V - 0.115
Bulb Life Entire life of the instrument
Cent Wavelengths 420 nm / 525 nm / 575 nm / 610 nm / 460 nm
Wavelength Accuracy +/- 2nm
Spectral Bandwidth Typ12 nm
Typical Use Bench/Portable
Principle of Operation Interference Filter Photometer, with four different wavelengths
Light Source Tungsten Submini Lamp 5 V - 0.115
Bulb Life Entire life of the instrument
Central Wavelengths 420 nm / 525 nm / 575 nm / 610 nm / 460 nm
Wavelength Acc +/- 2nm
SpeBandwidth Typ 12 nm
Typical Use Bench/Portable
Principle of Operation Interference Filter Photometer, with four different wavelengths
Light Source Tungsten Subminiature Lamp 5 V - 0.115
Bulb Life Entire life of the instrument
Central Wavelengths 420 nm / 525 nm / 575 nm / 610 nm / 460 nm
Wavelength Accuracy +/- 2nm
Spec Bandwidth Typical 12 nm
Typical Use Bench/Portable
Principle of Operation Interference Filter Photometer, with four different wavelengths
Light Source Tungsten Subminiature Lamp 5 V - 0.115
Bulb Life Entire life of the instrument
CentWavelengths 420 nm / 525 nm / 575 nm / 610 nm / 460 nm
Wavelength Accuracy +/- 2nm
Spect Bandwidth Typical 12 nm
Typical Use Bench/Portable
Principle of Operation Interference Filter Photometer, with four different wavelengths
Light Source Tungsten Subminiature Lamp 5 V - 0.115
Bulb Life Entire life of the instrument
Cent Wavelengths 420 nm / 525 nm / 575 nm / 610 nm / 460 nm
Wavelength Accuracy +/- 2nm
Spec Bandwidth Typical 12 nm
   
C216 for Swimming Pool testing C218 for Environmental Analysis C200 Over 40 parameter tests in 1 meter    
Typical Use Bench/Portable
Principle of Operation Interference Filter Photometer, with four different wavelengths
Light Source Tungsten Subminiature Lamp 5 V - 0.115
Bulb Life Entire life of the instrument
CentWavelengths 420 nm / 525 nm / 575 nm / 610 nm / 460 nm
Wavelength Accuracy +/- 2nm
Spectral Bandwidth Typ 12 nm
Typical Use Bench/Portable
Principle of Operation Interference Filter Photometer, with four different wavelengths
Light Source Tungsten Submin Lamp 5 V - 0.115
BulbLifEntirelifeofthe inst
Central Wavelengths 420 nm / 525 nm / 575 nm / 610 nm / 460 nm
Wavelength Acc +/- 2nm
Typical Use Bench/Portable
Principle of Operation Interference Filter Photometer, with four different wavelengths
Light Source Tungsten Subminiature Lamp 5 V - 0.115
Bulb Life Entire life of the instrument
Central Wavelengths 420 nm / 525nm /575 nm/ 610nm/ 460 nm
Wavelength Accuracy +/- 2nm
Spectral Bandwidth Typ 12 nm
   

COD - Chemical Oxygen Demand

What is COD Chemical Oxygen Dem C99 C.O.D. Multi-parameter meter C9800 Heating Reactor Block HI-93754A-25 Low Range COD Reagent HI-93754B-25 Medium Range COD Re
HI-93754C-25HighRange COD COD Waste Handling Service

Daha Fazla Bilgi in Mail Atabilirsiniz